質譜訊號峰形波形自動分析程式
質譜訊號峰形波形自動分析程式。
This is a mass spectrum analyzing program specially tailored to conveniently analyze spectrum data with groups of mass peaks that are equally spaced in mass. For example if you have a mass spectrum of N molecules of water, (H2O)_N, with N can be from 1~200, then you might want to consider trying out this program. It takes advantages of this equally-spaced nature of mass peaks and automates statistical analysis or fitting procedure from one peak to another (peak-by-peak). So you don’t need to analyze the above mentioned water mass spectra individually from N = 1 to 200. One of many useful features is it can also deal with time-of-flight (TOF) mass spectra where the equally-spaced peaks in mass is measured with a TOF mass spectrometer and you have output data mass peaks that are non-uniformly spaced. In this case the conversion from time to mass unit can be calibrated in the program by a innovative fitting procedure (also automated).
Full article's at:
https://docs.google.com/document/d/1fO-qp-B0qXzFHVuOb5xEPXVGT5jXAUmIt-7jdP5HBAQ/edit?usp=sharing
- 以Matlab寫成
- 於研究所期間與實驗室夥伴共同發展而成。
This is a mass spectrum analyzing program specially tailored to conveniently analyze spectrum data with groups of mass peaks that are equally spaced in mass. For example if you have a mass spectrum of N molecules of water, (H2O)_N, with N can be from 1~200, then you might want to consider trying out this program. It takes advantages of this equally-spaced nature of mass peaks and automates statistical analysis or fitting procedure from one peak to another (peak-by-peak). So you don’t need to analyze the above mentioned water mass spectra individually from N = 1 to 200. One of many useful features is it can also deal with time-of-flight (TOF) mass spectra where the equally-spaced peaks in mass is measured with a TOF mass spectrometer and you have output data mass peaks that are non-uniformly spaced. In this case the conversion from time to mass unit can be calibrated in the program by a innovative fitting procedure (also automated).
Full article's at:
https://docs.google.com/document/d/1fO-qp-B0qXzFHVuOb5xEPXVGT5jXAUmIt-7jdP5HBAQ/edit?usp=sharing
Mar 1, 2012
Wire mesh grid simulation in Simion
| Tof + voltage deflector + Einzel lens. Elements are intentially placed closer to each other to let see the finer details of the elements. |
Preface:
http://simion.com/info/grid.htmlWe want to compare the differences in electric field distortion between wire mesh plates and single-hole plates as voltage plates in our TOF mass spectrometer. The electric field can be simulated a program called Simion.
Ions accelerated by hole plates suffers a focusing effect (beam expansion):
Ions accelerated by mesh grid wires has 'less' focusing effect (trajectories are more parallel):
| The real thing. |
|
![]() |
| Fine grid voltage mesh simulation, CF a hole voltage plate. |
Potential contour details showing the distortions of electric field near the fine metal wires:
![]() |
| The vertical lines are the ions coming from top. Horizontal contours are the potential energy lines. |
| The real thing |
Simion 7 3D problems:
1. Directories in C:/Documents and settings/The One/ are not listed completely in directory tree window, even after the scan action performs. There is a warning on top of the file manage window saying "Warning, files nested too deep". Did not find a cure in the manual in the first try. Hope someone can help.